ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 7CP9 | |
in silico model | AlphaFold |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 13.924 |
f_angle_d | 0.673 |
f_chiral_restr | 0.042 |
f_plane_restr | 0.006 |
f_bond_d | 0.002 |
Sample |
---|
Complex of VDAC, TOM core and PINK1 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blot force 10 for 2 s. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 791000 |
Reported Resolution (?) | 2.75 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7CP9) | 2 | |||
Refinement Space | REAL | REAL | |||
Refinement Protocol | FLEXIBLE FIT | FLEXIBLE FIT | |||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/?**2) | 52.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | TFS KRIOS |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 105000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | 4.5 |
IMAGE ACQUISITION | EPU | 3 |
CTF CORRECTION | cryoSPARC | 4.5 |
MODEL FITTING | ISOLDE | 7 |
MODEL REFINEMENT | PHENIX | 1.21.1_5286 |
MODEL FITTING | ISOLDE | 7 |
MODEL REFINEMENT | PHENIX | 1.21.1_5286 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | Patch CTF | 5700000 | Picked using low resolution templates |