auxin transporter PIN8 as asymmetric dimer (outward/inward) with 4-CPA bound in the outward partly released state
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 7QP9 |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 9.91 |
f_angle_d | 0.532 |
f_chiral_restr | 0.04 |
f_plane_restr | 0.004 |
f_bond_d | 0.003 |
Sample |
---|
auxin transporter PIN8 as asymmetric dimer (outward/inward) with 4-CPA bound in the outward partly released state |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Wait 4 seconds after sample loading, Blotting time 4 seconds with blotting force of -1 before plunging |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 74729 |
Reported Resolution (?) | 3.43 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7QP9) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | 103.2 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/?**2) | 58.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 600 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | |
CTF CORRECTION | cryoSPARC | |
INITIAL EULER ASSIGNMENT | cryoSPARC | |
FINAL EULER ASSIGNMENT | cryoSPARC | |
CLASSIFICATION | cryoSPARC | |
RECONSTRUCTION | cryoSPARC | |
MODEL REFINEMENT | PHENIX | 1.19.2_4158: |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | CTF amplitude correction was performed following motion correction using cryosparc-live | 8093919 |