3H3W
Fitting of the gp6 crystal structure into 3D cryo-EM reconstruction of bacteriophage T4 dome-shaped baseplate
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 3H2T |
Data Collection
Overall | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID # | Resolution (High) | Resolution (Low) | Percent Possible (Observed) | Net I Over Average Sigma (I) | Redundancy | Number Reflections (All) | Number Reflections (Observed) | Observed Criterion Sigma (F) | Observed Criterion Sigma (I) | B (Isotropic) From Wilson Plot | |||||||||
1 | 12 |
Sample |
---|
bacteriophage T4 dome-shaped baseplate |
Sample Components |
ring of 12 molecules of gene product 6 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 945 |
Reported Resolution (?) | 12 |
Resolution Method | FSC 0.5 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C6 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (3H2T) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | KODAK SO-163 FILM | ||||||||
Electron Dose (electrons/?**2) | 25 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2001-01-30 |
Temperature (Kelvin) | |
Microscope Model | FEI/PHILIPS CM300FEG/T |
Minimum Defocus (nm) | 1200 |
Maximum Defocus (nm) | 5000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | GATAN LIQUID NITROGEN |
Nominal Magnification | 45000 |
Calibrated Magnification | 47000 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | SITUS COLORES | |
RECONSTRUCTION | SPIDER |