6G9O
Structure of full-length homomeric mLRRC8A volume-regulated anion channel at 4.25 A resolution
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 10.278 |
f_angle_d | 0.831 |
f_chiral_restr | 0.045 |
f_bond_d | 0.005 |
f_plane_restr | 0.004 |
Sample |
---|
Homohexameric mLRRC8A |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 34674 |
Reported Resolution (?) | 4.25 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | The cryo-EM density corresponding to the full-length mLRRC8A was resolved to 4.25 A in the presence of a soft solvent mask and after applying global C ... |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C3 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | |||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/?**2) | 1.1 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | 3200 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 46511 |
Calibrated Magnification | 46511 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | RELION | |
IMAGE ACQUISITION | SerialEM | |
CTF CORRECTION | CTFFIND | |
MODEL FITTING | Coot | |
INITIAL EULER ASSIGNMENT | RELION | |
FINAL EULER ASSIGNMENT | RELION | |
RECONSTRUCTION | RELION | |
MODEL REFINEMENT | PHENIX | |
MODEL REFINEMENT | REFMAC |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 105867 |